OIL AND GAS POWER SOLUTIONSDUBAI, UAE · ACROSS THE GCC

Engineered Power for Oil & Gas

SINTAQA designs, deploys and operates mobile and turnkey power systems that keep production running. We combine rental agility with deep engineering to cut lead time, lower cost and raise reliability across the GCC.

Oil refinery at dusk powered by industrial generators
SINTAQA / OIL & GAS
Segments: upstream, midstream and downstream
3
GCC countries served from Dubai
6
Plus rental models to lower total operating cost
PPA · BOOT
Registered vendor; approved generator units, tanks and components
ADNOC

You need an engineering partner, not a rental supplier.

We provide mobile, modular and turnkey power and energy services for oil and gas operations across the GCC. We combine rental agility with engineering depth to keep critical assets online in the most demanding environments.

In an industry where no two projects are the same, and where everything counts, we design, deliver and operate bespoke solutions that support your assets from construction, start-up and testing through production, maintenance and decommissioning: upstream, midstream and downstream.

Where we support oil and gas operations.

Containerised generator transported to a remote oil field site

Upstream

Drilling, production and remote field facilities, including flare-gas-to-power for captive loads.

Discuss a upstream project

Zone 2 generators, certified per unit.

Rental generators converted for Zone 2 hazardous areas with ATEX-certified components, each with an ATEX certificate issued for that specific SINTAQA unit.

SINTAQA supplies containerised diesel generators converted for Zone 2 hazardous areas, where an explosive gas atmosphere is not expected in normal operation but may occur for short periods: well sites, processing and compression facilities, refineries and tank farms.

SINTAQA 1,250 kVA generator units can be converted for Zone 2 applications using the required certified safety components and project-specific modifications. Certification and documentation are prepared for the converted unit in accordance with the applicable project and client requirements. Standard fleet units are not delivered as Zone 2 by default; conversion is project-specific. Certified SINTAQA units have already operated on client sites. A Zone 2 conversion includes:

  • ATEX- and ADNOC-approved air intake shutoff valve (Chalwyn D-series, II 2G Ex h IIB T3 Gb) that closes automatically to stop engine runaway if flammable gas is drawn in with the intake air
  • ATEX- and ADNOC-approved stainless steel 316L exhaust spark arrestor (Chalwyn, EN 1834), approved for Zone 1 and Zone 2 hazardous areas
  • ATEX product certificates for the fitted components, and an ATEX certificate issued for the converted unit
Request a Zone 2 generator
01

Certified per unit

The ATEX certificate is issued for the specific generator you receive, not for a type or a brochure.

02

ADNOC: vendor and equipment

SINTAQA is registered as a vendor with ADNOC. ADNOC-approved generator units are available for applicable ADNOC projects. ADNOC-approved fuel-tank configurations are available. ADNOC-approved components are used where required by project specifications.

03

Fleet convertible

Any relevant SINTAQA 1,250 kVA unit can be converted for Zone 2 for a project. Units are not delivered as Zone 2 by default.

04

Approved components

ADNOC-approved shutoff valves and spark arrestors from Chalwyn (AMOT, UK), widely used in the oil and gas industry.

What is a Zone 2 generator?

A Zone 2 generator is a generator adapted and certified to run in a Zone 2 hazardous area, where an explosive gas atmosphere is not expected in normal operation and would only be present briefly. An air intake shutoff valve stops the engine running away on ingested gas, and an exhaust spark arrestor stops hot particles leaving the exhaust.

Zone 2 conversion on SINTAQA generators
ComponentFunction
Air intake shutoff valveRunaway protection: closes if flammable gas is drawn in with intake air
Exhaust spark arrestorControls the ignition risk from hot exhaust particles
Certification and documentationATEX product certificates for the components and an ATEX certificate for the specific converted unit
Conversion is project-specific: standard fleet units are not delivered as Zone 2 by default, and certification is prepared for each converted unit.
Zone 2 generator packageA generator module with an air intake shutoff valve that closes to stop engine overspeed if flammable gas is drawn in, and an exhaust spark arrestor that stops hot particles leaving the exhaust.Generator moduleAir intake shutoffExhaust spark arrestor+ ATEX certificates for the fitted components and for the converted unit
Conceptual. The final Zone 2 scope follows the site's hazardous-area classification and client requirements.

Full details, zone definitions and what the site operator needs to confirm: Zone 2 generator rental.

Power solutions for oil and gas.

Our solutions are engineered to:
01

Meet performance targets on time and on budget

02

Optimise production and process stability

03

Reduce carbon intensity via diesel-to-gas conversions, flare-gas-to-power and hybrid integrations

04

Lower total operating cost through PPA, BOOT and rental models

05

Cut lead times with containerised, plug-and-play packages and standardised interfaces

06

Minimise downtime using remote monitoring, predictive maintenance and fast-swap spares

07

Maintain HSE excellence in line with regional and client standards, using ADNOC-approved generator units, fuel-tank configurations and components where required

08

Perform reliably in harsh onshore and offshore conditions

SINTAQA field engineer servicing a generator for an oil and gas site

An engineering-led team

By partnering with SINTAQA, you gain an engineering-led team with domain expertise, regional project experience and the tools to execute, from power plant design and integration to commissioning and long-term O&M.

We invest in technology and people so you get efficient, reliable equipment and skilled specialists to implement it: modern gas and diesel fleets, hybrid and storage options, advanced controls and SCADA, transformers and switchgear, and continuous performance oversight.

SINTAQA – engineered power, delivered.

Discuss your oil and gas project

Share the site, required power and schedule. Our engineers will come back with a configured solution.

By submitting the form, you agree to the privacy policy.
WhatsApp